Danfoss D1P Open Circuit High Power Axial Piston Pump
Danfoss D1P Open Circuit High Power Axial Piston Pump
Danfoss D1P Pump is designed for high performance and reliability in heavy duty applications. If you are looking for Danfoss D1P Open Circuit High Power Axial Piston Pump repair, Contact Rote x Hydraulic today. we are leading supplier and services provider .
- Axial Piston Pump
- Variable displacement Pump
- Series D1P Pump Model : 130 / 145 / 193 / 260.
- D1P High Power Open Circuit Pumps
- Minimum Pressure 350 Bar (Psi 5076)
- Maximum Pressure 400Bar (Psi 5802)
- Open circuit
Share Product :
- Description
- Technical Specifications
- Product Model
- Data Link
Danfoss Frame L Open Circuit Axial Piston Pump Series 45 is developed in variable displacement, axial piston swashplate and single servo piston design for open circuit applications. These products are available to optimize performance, size and cost as per the work function requirement of the demanding mobile equipment marketplace.
These pump have control ports system pressure to the servo piston, adjusting swashplate angle to control pump output flow. Frame L pumps come in two sizes 25 cm³ to 30 cm³, with the nominal pressure up to 260 [3770 psi] bar and 210 [3045 psi] bar and maximum pressure up to 350 [5075 psi] bar and 300 [4350 psi] bar. These pumps are available with variety of control system options including load sensing and pressure compensated. Their through-drive capability for multi-circuit systems makes them versatile, Moreover, Frame L pumps are designed with a range of mounting flanges, shafts, and porting options for ease of installation. These pumps are used in numerous mobile equipment such as Cranes, Telescopic handlers, Forklift trucks, Wheel loaders, Sweepers and Backhoe loaders.
Danfoss Frame L Open Circuit Axial Piston Pump Series 45 are known for reliability and higher performance due to their robust input shaft bearings to handle large external shaft loads and Integrated gauge ports for monitoring operating conditions. Additionally, these come with Customer-driven using quality function deployment (QFD) and design for manufacturability (DFM) techniques.
Technical Data
Features | Unit | 65 | 130 | 145 | 160 | 193 | 260 | 290 | ||||
No impeller | No impeller | No impeller | No impeller | No impeller | No impeller | No impeller | No impeller | No impeller | No impeller | |||
Displacement | cm³ [in³] | 65 [3.84] | 130 [7.93] | 130 [7.93] | 145 [8.85] | 145 [8.85] | 160 [9.77] | 160 [9.77] | 193 [11.78] | 260 [15.87] | 290 [17.70] | |
Available rotation | CCW [L] | - | - | - | - | - | - | - | - | - | - | |
CW [R] | - | - | - | - | - | - | - | - | - | - | ||
Weight | kg [lbs] | 47 [104] | 68 [150] | 74 [163] | 68 [150] | 74 [163] | 68 [150] | 74 [163] | 106 [234] | 141 [311] | 141 [311] | |
Input speed | Min | rpm | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
Rated | rpm | 2550 | 2200 | 2550 | 2200 | 2550 | 2200 | 2500 | 2500 | 2300 | 2300 | |
Max | rpm | 3000 | 2500 | 2500 | 2200 | 2500 | 2200 | 2500 | 2500 | 2300 | 2300 | |
Theoretical flow | l/min [US gal/min] | 165 [44] | 286 [76] | 325 [86] | 319 [84] | 363 [96] | 400 [106] | 400 [106] | 483 [128] | 598 [158] | 667 [176] | |
System pressure | Max. working pressure | bar [psi] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] | 350 [5076] |
Max Pressure | bar [psi] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | 400 [5802] | |
Inlet pressure | Min | bar [psi] | 0.8 [11.6] | 0.8 [11.6] | 0.6 [8.7] | 0.8 [11.6] | 0.6 [8.7] | 0.6 [8.7] | 0.6 [8.7] | 0.6 [8.7] | 0.6 [8.7] | 0.6 [8.7] |
Max | bar [psi] | 30 [435] | 30 [435] | 2 [29 | 30 [435] | 2 [29 | 30 [435] | 2 [29 | 2 [29 | 2 [29 | 2 [29 | |
Case pressure | bar [psi] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] | 2 [29] |